A gas water heater rarely fails silently. The pilot, the flame and the vent tell you which part of the sequence has stopped working, if you read them in order.
The safety sequence
A standing-pilot unit runs a small flame at the burner. The thermocouple or thermopile sits in that flame and generates a signal that holds the gas valve open. If the signal drops, the valve closes. That is why a pilot that will not hold after the button is released points at the sensor, the flame or the orifice rather than the thermostat.
Electronic ignition units replace the standing pilot with a spark and a flame sensor. A unit that sparks but does not light may have a gas supply problem; one that lights and then shuts down may not be proving flame.
Burner, valve and thermostat
If the pilot holds but the burner does not fire, the thermostat is not calling or the valve is not opening. If the burner fires but the water stays warm, the flame may be partly blocked, the thermostat may be set low, or a dip tube may be mixing cold water into the outlet. These are different faults and should not be treated as one.
Venting in a mid-century closet
Cumberland South's original closets were built around atmospheric-vent tanks. A replacement can sit closer to the vent hood, change the draft or require different clearances. Stored paint, solvents and cardboard in the same closet can also affect combustion air.
A vent with holes, separated joints or a blocked flue is a shutdown condition. So is a nest or debris at the termination.
Stop-work signs
- Gas smell or hissing at the valve.
- A damaged or disconnected flue.
- A flame that is yellow, lifting or floating.
- Water at the tank base or a relief valve that is capped.
Repair or replacement
A thermocouple, igniter, flame sensor or gas valve on a sound tank is a repair. A leaking shell, a corroded base or a vent route that cannot be corrected is a replacement. In an older closet, the vent and combustion-air question often decides which path is realistic.
Installation covers the vent and unit fit; maintenance covers the annual burner and flue check.