A water heater leak is a location problem before it is a parts problem. The same puddle can come from a tired T&P valve, a drain valve that no longer seats, a threaded fitting, a cracked dip tube, a failed tank shell or, on a tankless unit, a blocked condensate line. Each has a different repair and a different cost, and none of them is solved by replacing the whole unit without looking.
We trace the source, repair what can be repaired, and say plainly when the tank is finished.
Start with where the water appears
From the T&P valve or its discharge pipe. The temperature-and-pressure relief valve is a safety device. It opens when pressure or temperature exceeds its setting. A drip can mean the valve is weak, the system is closed and has nowhere to absorb expansion, or the tank is overheating. Capping the valve to stop the drip removes the safety function and is not a repair.
From the drain valve at the bottom. Sediment can keep the valve from reseating after it has been used, and the packing or washer can fail. This is usually a valve repair or replacement rather than a tank problem.
From the inlet or outlet fitting on top. Threaded nipples, unions and dielectric fittings are common leak points, especially after years of thermal cycling. Water here can run down the side of the tank and look like a bottom leak.
From the tank shell or the base. Rust streaks, water weeping through the metal or a soft, corroded base point to the tank itself. This is the case where replacement is usually the honest answer, because the steel is thinning from the inside.
Under a tankless unit. Condensate is the first suspect, followed by isolation valves and internal fittings. A tankless unit does not hold a tank of water, so a puddle is a routing or fitting issue more often than a heat-exchanger failure.
Only when the burner runs. A leak that appears during heating and stops afterwards points toward expansion pressure or a T&P valve doing its job. A leak that runs constantly points toward supply pressure or a fitting.
What the assessment checks
We isolate the unit, dry the area and watch where water returns. Then we check the valve settings, the inlet pressure where it can be measured, the expansion control, the age and condition of the fittings and the tank base. On a gas unit, the flue and combustion area are checked for water damage; on an electric unit, the element seals and wiring are checked for moisture.
The result is one of three answers:
- A repairable component — valve, fitting, union, pipe, condensate route. The repair is scoped and the tank stays.
- A repairable component on a tank near the end — the leak can be fixed, but the anode and sediment suggest the unit is living on borrowed time. You get both facts and decide.
- A failed tank — the shell is corroding, and replacement is the realistic path.
What to do before we arrive
If the leak is active and you can reach the valve safely:
- Close the cold-water inlet valve on top of the tank.
- Turn off the breaker for an electric heater, or set the gas control valve to off.
- Open a hot tap to relieve pressure if the plumbing allows it.
- Move anything water can damage and keep the area clear.
Do not stand in water to reach an electrical panel, and do not try to stop a leak by tightening a gas line. If you smell gas, leave the building and call your gas utility or 911 from outside. Emergency water heater repair covers the active-leak sequence in more detail.
Repair or replace
A fitting leak on a tank with a healthy anode and no scale problem is a straightforward repair. A shell leak is not repairable in any meaningful sense. Between those extremes, the decision rests on the tank's age, the condition of the anode, how much sediment has collected and whether the current unit is correctly sized and strapped.
For a replacement, the Sunnyvale permit and inspection are part of the job, not an optional extra: a residential unit under 150 gallons replaced in the same location needs the city permit and a final inspection, with an electrical inspection for a new electric heater. Seismic strapping is placed in the upper and lower thirds, at least 4 inches above the controls, with the count scaled to tank size.
Related work
A leak is sometimes the first sign of a pressure problem, so tank water heater repair and maintenance are worth reading alongside this page. A leaking gas unit may also need gas water heater repair; an electric unit with moisture in the element area may need electric water heater repair.
Call (989) 601-2666 with where the water is appearing and whether it runs constantly or only during heating.