A tankless water heater fails differently from a storage tank. There is no tank full of hot water to run out, so the complaints are usually about the unit not firing, firing and shutting down, giving inconsistent temperature, or showing a code. In Sunnyvale, scale is the thread that runs through most of those symptoms.
Scale is the local problem
A tankless unit heats water as it passes through a copper or stainless heat exchanger. Minerals in hard water deposit on the inside of that exchanger, and the deposit insulates the metal from the water. The unit then needs a higher temperature to deliver the same hot water, the exchanger runs hotter, and efficiency and component life both suffer. The manufacturer's service guidance is explicit that hard water causes this and that the deposits must be removed.
Sunnyvale's supply is a blend: the 2025 water quality report averages 60 ppm hardness for SFPUC water in the north, 97 ppm for Valley Water in the south and 290 ppm for city wells used at summer peaks and in emergencies. A property on the harder blend accumulates scale faster, so the descaling interval should follow the water and the manufacturer's schedule rather than a fixed annual habit.
Descaling is not a flush of a tank. The unit is isolated, a pump circulates food-grade white vinegar through the heat exchanger, and the model's own procedure is followed — including any bypass cartridge a particular unit requires. Doing it without isolation valves, or with the wrong cartridge, can damage the unit.
Not firing, or firing briefly
A gas tankless unit ignites on demand. When it does not, the cause is in one of four areas:
- Water flow — the unit needs a minimum flow to activate. A restricted aerator, a partly closed valve or a failing flow sensor can leave it waiting.
- Ignition — the igniter, gas supply or gas valve. A code for ignition failure sends the diagnosis toward spark, gas pressure and the burner.
- Flame sensing — a flame sensor that cannot see the flame will shut the burner down even when it lit. False-flame codes point the other way: a sensor reporting flame when there is none.
- Air and venting — a blocked intake, a fan fault or a condensate problem can prevent or interrupt firing.
The code narrows the area, but the same number can mean different things across brands. The model's fault table plus live checks decide the repair; clearing the code and hoping is not a diagnosis.
Temperature that will not hold
Inconsistent temperature at a tap can come from scale, a flow sensor that reads inaccurately, a mixing valve at a fixture, or a demand that exceeds the unit's capacity when two fixtures run at once. The distinction matters: a capacity limit is not a repair, while a scaled exchanger or a failing sensor is.
What the assessment covers
- The error history and the conditions under which the fault appears.
- Water flow at the unit and at the fixtures, including the activation threshold.
- Gas supply and pressure on a gas unit.
- The heat exchanger's condition and the descaling history.
- Venting, air intake and condensate routing.
- The isolation valves, which make future descaling possible.
Maintenance and replacement
A tankless unit that is scaled but intact can be descaled and returned to service. A heat exchanger damaged by repeated scale, a failed control board or a leaking internal component may point to replacement. Installation decisions — gas line sizing, venting, condensate and clearances — are covered under water heater installation, and the regular service under water heater maintenance.
For gas-side faults that are not specific to tankless operation, gas water heater repair is the companion page. If the unit is leaking, start with leak repair.
Call (989) 601-2666 with the model, the code and whether the problem happens at one fixture or everywhere.